Filter
1.
Article in English | IMSEAR | ID: sea-140043

ABSTRACT

Implant stability is a requisite characteristic of osseointegration. Without it, long-term success cannot be achieved. Continuous monitoring in a quantitative and objective manner is important to determine the status of implant stability. Measurement of implant stability is a valuable tool for making decisions pertaining to treatment protocol and also improves dentist-patient communication. Owing to the invasive nature of histological analysis, various others methods have been proposed like radiographs, cutting torque resistance, reverse torque, modal analysis, resonance frequency analysis and Implatest® . This review focuses on objectives and various methods to evaluate implant stability.


Subject(s)
Dental Implantation, Endosseous/standards , Dental Implants , Dental Prosthesis Retention , Dental Restoration, Permanent/standards , Dental Stress Analysis/methods , Dental Stress Analysis/standards , Evaluation Studies as Topic , Humans , Validation Studies as Topic
2.
Braz. oral res ; 20(3): 241-246, Jul.-Sept. 2006. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-435813

ABSTRACT

The aim of this study was to assess the displacement of posterior teeth in maxillary complete dentures stored in water at 37°C. Twenty acrylic resin-based maxillary complete dentures were constructed with the anterior teeth arranged in normal overlap and the posterior teeth in Angle class I. Metallic pins were placed on the labial cusp of the first premolars (PM), and on the mesiolabial cusp of the second molars (M). The final acrylic resin pressing was made in a metallic flask with aid of the RS tension system, and polymerized in a moist-hot cycle at 74°C for 9 hours. The dentures were deflasked after cooling in their own polymerizing water or after cooling in polymerizing water plus bench storage for 3 hours, and stored in water at 37°C for periods of 7, 30, and 90 days. Following deflasking and after each storage period tested, the PM-PM (premolar to premolar), M-M (molar to molar), LPM-LM (left premolar to left molar), and RPM-RM (right premolar to right molar) distances were measured with an STM Olympus microscope, with an accuracy of 0.0005 mm. Collected data were submitted to ANOVA and Tukey's test (5 percent). There was no statistically significant difference for the PM-PM, M-M, and LPM-LM distances after all storage periods when the flask cooling methods were considered. With exception of the RPM-RM distance after the 30-days water plus bench storage period, the other distances remained statistically stable.


O propósito deste trabalho foi verificar a movimentação de dentes posteriores em prótese total superior armazenada em água a 37°C. Vinte próteses totais superiores foram confeccionadas com resina acrílica, com os dentes anteriores em transpasse normal e os posteriores em Classe I de Angle. Pinos metálicos foram colocados na cúspide vestibular dos primeiros pré-molares (PM) e cúspide mésio-vestibular dos segundos molares (M). A prensagem final da resina acrílica foi feita em mufla metálica com auxílio do dispositivo RS de contensão e a polimerização em ciclo de água a 74°C durante 9 horas. As próteses foram demufladas após esfriamento em água de polimerização ou em água de polimerização mais armazenagem em bancada por 3 horas e armazenadas em água a 37°C pelos períodos de 7, 30 e 90 dias. Após demuflagem e após cada período de armazenagem em água, as distâncias PM-PM (pré-molar a pré-molar), M-M (molar a molar), PMD-MD (pré-molar direito a molar direito) e PME-ME (pré-molar esquerdo a molar esquerdo) foram medidas com microscópio Olympus STM, com precisão de 0,0005 mm. Os dados coletados foram submetidos à análise de variância e ao teste de Tukey com significância de 5 por cento. Em todos os períodos de armazenagem, as distâncias PM-PM, M-M e PME-ME não apresentaram diferenças estatisticamente significativas quando as muflas foram esfriadas pelos dois métodos. Com exceção da distância PMD-MD no período de 30 dias de armazenagem em água mais bancada, as demais distâncias permaneceram sem diferença estatística significativa.


Subject(s)
Dental Stress Analysis/standards , Denture, Complete, Upper/standards , Tooth, Artificial/standards , Water , Acrylic Resins , Analysis of Variance , Denture Bases , Denture Design , Freezing , Materials Testing , Temperature , Time Factors , Water/chemistry